Login for faster access to the best deals. Click here if you don't have an account.

LPG hose Full-time Job

1 year ago Executive / Head Chef Davangere   39 views
Job Details

 

The SAE standards

SAE answers those questions with its J517 hydraulic hose standard. This LPG hose standard serves as the most popular benchmark in the realm of industrial hydraulics today. More specifically, J517 is a set of guidelines that applies to the current SAE 100R series of hoses. Currently, 16 such hose styles exist, and they are designated as 100R1 through 100R16 (see descriptions, pages A105 and 106). Each of the styles must meet a set of dimensional and performance characteristics as set forth by SAE. However, SAE issues no approval source lists, certification, or letters of approval-conformance to these standards by manufacturers is strictly voluntary. In short, the standards only assure a similarity of products among different manufacturers.

 

Hydraulic hose construction

Modern hydraulic hose typically consists of at least three parts: an inner tube that carries the fluid, a reinforcement layer, and a protective outer layer.

 

The inner tube must have some flexibility and needs to be compatible with the type of fluid it will carry. Commonly used compounds include synthetic rubber, thermoplastics, and PTFE, sometimes called Teflon. The reinforcement layer consists of one or more sheaths of braided wire, spiral-wound wire, or textile yarn. The outer layer is often weather-, oil-, or abrasion-resistant, depending upon the type of environment the hose is designed for.

 

Not surprisingly, hydraulic hoses have a finite life. Proper sizing and use of the correct type of TPR LPG hose will certainly extend the life of a hose assembly, but there are many different factors that affect a hose's lifespan. SAE identifies some of the worst offenses as:

 

flexing the hose to less than the specified minimum bend radius

twisting, pulling, kinking, crushing, or abrading the hose

operating the hydraulic system above maximum or below minimum temperature

exposing the hose to rapid or transient rises (surges) in pressure above the maximum operating pressure, and

intermixing hose, fittings, or assembly equipment not recommended as compatible by the manufacturer or not following the manufacturer's instructions for fabricating hose assemblies.

Selecting the proper hose

Here are seven recommended steps the system designer should follow during the hose and coupling selection process. To help determine the proper hose for an application, use the acronym STAMPED - from Size, Temperature, Application, Materials, Pressure, Ends, and Delivery. Here is what to consider in each area:

 

Size - In order to select the proper hose size for replacement, it is important to measure the inside and natural gas hose diameters exactly using a precision-engineered caliper, as well as the length of the hose. Hose OD is particularly important when hose-support clamps are used or when hoses are routed through bulkheads. Check individual hose specification tables for ODs in suppliers' catalogs. When replacing a hose assembly, always cut the new hose the same length as the one being removed. Moving components of the equipment may pinch or even sever too long a hose. If the replacement hose is too short, pressure may cause the hose to contract and be stretched, leading to reduced service life.

 

Changes in hose length when pressurized range between +2% to 4% while hydraulic mechanisms are in operation. Allow for possible shortening of the hose during operation by making the hose lengths slightly longer than the actual distance between the two connections.

 

Temperature - All hoses are rated with a maximum working temperature ranging from 200° to 300° F based on the fluid temperature. Exposure to continuous high temperatures can lead to hoses losing their flexibility. Failure to use hydraulic oil with the proper viscosity to hold up under high temperatures can accelerate this problem. Always follow the hose manufacturer's recommendations.

 

Exceeding these temperature recommendations can reduce hose life by as much as 80%. Depending on materials used, acceptable temperatures may range from -65° F (Hytrel and winterized rubber compounds) to 400° F (PTFE). External temperatures become a factor when hoses are exposed to a turbo manifold or some other heat source.

 

When hoses are exposed to high external and internal temperatures concurrently, there will be a considerable reduction in hose service life. Insulating sleeves can help protect hose from hot equipment parts and other high temperature sources that are potentially hazardous. In these situations, an additional barrier is usually required to shield hydraulic fluid from a potential source of ignition.

 

Application - Will the selected hose meet bend radius requirements? This refers to the minimum bend radius (usually in inches) that a hydraulic hose must meet. Exceeding this bend radius (using a radius smaller than recommended) is likely to injure the hose reinforcement and reduce hose life.

 

Route high-pressure hydraulic lines parallel to machine contours whenever possible. This practice can help save money by reducing line lengths and minimizing the number of hard-angle, flow-restricting bends. Such routing also can protect lines from external damage and promote easier servicing.

 

Materials - It is mandatory to consult a compatibility chart to check that the tube compound is compatible with the fluid used in the system. Elevated temperature, fluid contamination, and concentration will affect the chemical compatibility of the tube and fluid. Most hydraulic hoses are compatible with petroleum-based oils. Note that new readily biodegradeable or green fluids may present a problem for some csa natural gas hose.

 

Pressure capabilities - Hose working pressure must always be chosen so that it is greater than or equal to the maximum system pressure, including pressure spikes. Pressure spikes greater than the published working pressure will significantly shorten hose life.

 

Hose ends - The coupling-to-hose mechanical interface must be compatible with the hose selected. The proper mating thread end must be chosen so that connection of the mating components will result in leak-free sealing.

 

There are two general categories of couplings to connect most types of hose: the permanent type (used primarily by equipment manufacturers, large-scale rebuilders, and maintenance shops) and the field-attachable type.

 

Permanently attached couplings are cold-formed onto the hose with powered machinery. They are available for most rubber and thermoplastic hoses and offer a wide range of dependable connections at low cost. Assemblies made in the field with portable machines are relatively simple; these machines are economical and easy to operate. In most cases, it is not necessary to skive the cover. These couplings are less complicated to install than other types.

 

Field-attachable couplings are classified as screw-together and clamp-type. The screw-together coupling attaches to the hose by turning the outer coupling shell over the outside diameter of the hose. The coupling insert is then screwed into the coupling shell. A clamp-type coupling has a 2-piece outer shell that clamps onto the hose OD with either two or four bolts and nuts.

This hose should be used in low pressure and vacuum applications, with petroleum- and water-based hydraulic fluids, within a temperature range from -40° to 100° C.

It is constructed with an inner tube of oil-resistant synthetic rubber, a reinforcement consisting of a ply, or plies, of woven or braided textile fibers with a suitable spiral of body wire, and an oil- and weather-resistant synthetic rubber cover.

 

This hose should be used with petroleum- and water-based hydraulic fluids, within a temperature range from -40° to 100° C.

It is constructed with an inner tube of oil-resistant synthetic rubber reinforced with two textile braids separated by a high-tensile-strength steel-wire braid. All of the braids are impregnated with an oil- and mildew-resistant synthetic rubber compound.

 

This high-pressure csa natural gas hose kit should be used with synthetic, petroleum- and water-based hydraulic fluids within a temperature range from -40° to 93° C.

It consists of a thermoplastic inner tube resistant to hydraulic fluids with suitable synthetic-fiber reinforcement and a hydraulic fluid- and weather-resistant thermoplastic cover. Nonconductive 100R8 is identified with an orange cover and appropriate lay line. Its pressure capacity is similar to that of 100R2.

 

Company Description
Eeffrrr131